Page 4 Rev. A, 06/13
DKC Power Consumption 12V 24V
DKC (excluding keypads) 250 mA 250 mA
DK-37 or DK-38 Keypad (each) 100 mA 100 mA
Electronic Lock Consult lock manual Consult lock manual
Aperio Hub (each) 250 mA 250 mA
Table 1: DKC Power Consumption
Connecting the Keypad Cable to the CPU Board
There are 9 color coded wires in the keypad cable. Refer to Figure 1 and Table 2 below and
connect each wire to the indicated terminal on the CPU board.
Overview of CPU Board
UC D
DOOR POS
REX
HC D
D1
DO
+ 12V
LED - Y
LED - R
LED - G
( - )
TAMP
BUZ
EXP POR T
USB
PORT
BATTERY
NONC COMNONC COMNONC COMNONC COM
++--
Door 1
Door 2
UC D
DOOR POS
REX
HC D
D1
DO
TAMP
BUZ
DOOR 1 DOOR 2 OPTION 2 OPTION 3
12-24V AC/DC
DC OUT 1 DC OUT 2
1A 1A
NONC COM
OPTION 1
Man Trap
Fa cility O nly 2
Fa cility O nly 1
+
F6 F1
F2
F3
F4
F5
Figure 1
MAIN IN
( - )
LED - Y
LED - R
LED - G
+ 12V
+ 12V
+ 12V
J9J8 J10 J11
DKC
Terminal
DKC Wiring
Reference
Suggested Wire
Color
DK-38
Terminal
+12V Positive DC supply lead
Red
DC+
D0 Wiegand data zero Green D0
D1 Wiegand data one White D1
LED-G Green light Orange GRN
LED-R Red light Brown RED
LED-Y Yellow light Blue YEL
BUZ Audible buzzer Yellow BUZ
TAMP Tamper indicator Purple TAMP
(-) Ground Black GND
Table 2: Wiring Terminal Connections
Note that suggested wire color for ‘LED-Y’ terminal is BLUE and suggested wire color for ‘BUZ’
terminal is YELLOW.
Power and Electric Lock Wiring